Time: 2025/5/1 22:17:29
Type: yichang0:
Message: {"mainDatalist":[{"fieldNames":["sfcwsp","cbhs","sfsp","cpjg","jsyyfx","tdrgh","guid","tdr","tdbm","tdrq","dwmc","dwbh","rq","cpmc","cpbh","ph","gg","zrbz","zrbm","ly","rk","sfxg","jl","yyfx","psjg"],"fieldValues":["是","
应收德昉 |
|
|
|
|
|
|
|
|
|
生产批次 | 产品名称 | 总材料成本 | 总数量 | 报废单位成本 | 报废数量(kg) | 直接材料 | 直接人工 | 制造费用 | 报废成本合计 |
2503276 | 双向拉伸聚酯/铝箔/聚乙烯药品包装用复合膜(注射用头孢他啶/氯化钠注射液(2.0g)上膜) | 26503.4 | 1028.60 | 25.77 | 445 | 11466.08 | 1039.65 | 2945.67 | 15451.40 |
","是","PET12/AL16/PE70","原材料厚薄不均生产过程不易发现导致。","099","YYF/JL/WL/033","汤畅","质量管理部","2025-04-23","惠州德昉高分子膜材料有限公司","057","","双向拉伸聚酯/铝箔/聚乙烯药品包装用复合膜(注射用头孢他啶/氯化钠注射液(2.0g)上膜)","1.263.01.0006","2503276","140mm","","","车间","","","德昉PE 720*12 厚薄不一至 造成北京锐业双向拉伸聚酯/铝箔/聚乙烯药品包装用复合膜(注射用头孢他啶/氯化钠注射液 ) 报废成品:445KG","分切过程中,对分切好的成品进行称重,单卷重量误差有0.8-1公斤,经测量厚度片薄10μm左右。经判定不符合客户要求。所造成经济损失请采购与供应商协商处理。","1、经对每卷膜抽样检测分析,挑选出来异常的卷膜厚度整体偏薄,数值为负偏差(实测厚度平均值:96.5-105.2微米,标准偏差范围为:95.7-112.3微米),实际平均厚度值在范围内,与标准样比对手感稍偏薄;2、该问题主要原因为内层PE膜厚度偏差大且为负偏差,其它余料和留样复测未发现异常;3、出函通知供应商分析原因并进行改善;4、经综合评估并经领导同意,该批膜单独包装做一个批号进行让步放行发货;5、通知业务经理提前与客户沟通并跟踪使用情况。"],"tableName":"unqua"}],"detailedDataList":[{"fieldNames":["xhdh","cpbh","cp","gg","rq","ph","sl","yy"],"fieldBigValues":[[""],[""],[null],[""],[""],[""],["0"],[null]],"tableName":"unqub"},{"fieldNames":["tb004","tb001","tb002","tb005","tb003","tb006","tb007"],"fieldBigValues":[["2503276"],["1.263.01.0006"],["双向拉伸聚酯/铝箔/聚乙烯药品包装用复合膜(注射用头孢他啶/氯化钠注射液(2.0g)上膜)"],["北京锐业制药(潜山)有限公司"],["140mm"],["PET12/AL16/PE70"],["445KG"]],"tableName":"unquc"}],"flowGuid":"c100d43a-12e3-41f9-ad7c-35aeb077a719"}
-----------------------------------------------------------
Time: 2025/5/1 22:17:29
Type: yichang1:
Message: {"mainDatalist":[{"fieldNames":["sfcwsp","cbhs","sfsp","cpjg","jsyyfx","tdrgh","guid","tdr","tdbm","tdrq","dwmc","dwbh","rq","cpmc","cpbh","ph","gg","zrbz","zrbm","ly","rk","sfxg","jl","yyfx","psjg"],"fieldValues":["是","应收德昉 |
|
|
|
|
|
|
|
|
|
生产批次 | 产品名称 | 总材料成本 | 总数量 | 报废单位成本 | 报废数量(kg) | 直接材料 | 直接人工 | 制造费用 | 报废成本合计 |
2503276 | 双向拉伸聚酯/铝箔/聚乙烯药品包装用复合膜(注射用头孢他啶/氯化钠注射液(2.0g)上膜) | 26503.4 | 1028.60 | 25.77 | 445 | 11466.08 | 1039.65 | 2945.67 | 15451.40 |
","是","PET12/AL16/PE70","原材料厚薄不均生产过程不易发现导致。","099","YYF/JL/WL/033","汤畅","质量管理部","2025-04-23","惠州德昉高分子膜材料有限公司","057","","双向拉伸聚酯/铝箔/聚乙烯药品包装用复合膜(注射用头孢他啶/氯化钠注射液(2.0g)上膜)","1.263.01.0006","2503276","140mm","","","车间","","","德昉PE 720*12 厚薄不一至 造成北京锐业双向拉伸聚酯/铝箔/聚乙烯药品包装用复合膜(注射用头孢他啶/氯化钠注射液 ) 报废成品:445KG","分切过程中,对分切好的成品进行称重,单卷重量误差有0.8-1公斤,经测量厚度片薄10μm左右。经判定不符合客户要求。所造成经济损失请采购与供应商协商处理。","1、经对每卷膜抽样检测分析,挑选出来异常的卷膜厚度整体偏薄,数值为负偏差(实测厚度平均值:96.5-105.2微米,标准偏差范围为:95.7-112.3微米),实际平均厚度值在范围内,与标准样比对手感稍偏薄;2、该问题主要原因为内层PE膜厚度偏差大且为负偏差,其它余料和留样复测未发现异常;3、出函通知供应商分析原因并进行改善;4、经综合评估并经领导同意,该批膜单独包装做一个批号进行让步放行发货;5、通知业务经理提前与客户沟通并跟踪使用情况。"],"tableName":"unqua"}],"detailedDataList":[{"fieldNames":["xhdh","cpbh","cp","gg","rq","ph","sl","yy"],"fieldBigValues":[[""],[""],[null],[""],[""],[""],["0"],[null]],"tableName":"unqub"},{"fieldNames":["tb004","tb001","tb002","tb005","tb003","tb006","tb007"],"fieldBigValues":[["2503276"],["1.263.01.0006"],["双向拉伸聚酯/铝箔/聚乙烯药品包装用复合膜(注射用头孢他啶/氯化钠注射液(2.0g)上膜)"],["北京锐业制药(潜山)有限公司"],["140mm"],["PET12/AL16/PE70"],["445KG"]],"tableName":"unquc"}],"flowGuid":"c100d43a-12e3-41f9-ad7c-35aeb077a719"}
-----------------------------------------------------------